FS9Z-B1218FS1A-C11SSafety ControllerSafetyOneUser’s manual

Strany 3 - SAFETY PRECAUTIONS

LOGIC 5-52 Timing chart (Logic 11C) Example: Manual start input (X16) is used. Example: Control start input (X17) is used. Safety output 2

Strany 4

LOGIC 5-53 Chapter 5

Strany 5

LOGIC 5-54 Logic 11d: Muting function logic for apparatus with openings Overview (Logic 11d) The logic is for using safety devices with dual channel s

Strany 6

LOGIC 5-55 Chapter 5 Logic circuit (Logic 11d) X0, X1X2, X3X4, X5X6, X7T12, X12, T13, X13T10, X10, T11, X11T14, X14T15, X15X16X1 7Safety input 1Safety

Strany 7 - BEFORE GETTING STARTED

LOGIC 5-56 Functions (Logic 11d) ●Safety inputs: X0, X1, X4, X5, and X10 to X13 (T10 to T13) Safety inputs are used to diagnose the status of connect

Strany 8 - CONTENTS

LOGIC 5-57 Chapter 5 ●Muting inputs: X2, X3, X6, and X7 Muting inputs are used to diagnose the status of muting devices, such as sensors or limit swi

Strany 9

LOGIC 5-58 ●External device monitor inputs: X14 and X15 (T14 and T15) External device monitor inputs are used to diagnose the status of devices conne

Strany 10

LOGIC 5-59 Chapter 5 ●Start inputs: X16 and X17 Start inputs are used to control the start of safety outputs. Intended inputs (Terminal names) Ta

Strany 11 - Chapter1 OVERVIEW

LOGIC 5-60 ●Safety outputs: Y0 to Y3 Safety outputs are used to output safety information processed by SafetyOne. Intended outputs (Terminal names)

Strany 12 - Features of the SafetyOne

LOGIC 5-61 Chapter 5 ●Safety input monitor outputs: Y4 to Y11 Safety input monitor outputs are used to output the status of safety inputs in SafetyOn

Strany 13 - Parts Description

OVERVIEW 1-1 Chapter 1 Chapter1 OVERVIEW This chapter provides an understanding of the SafetyOne. Make efficient use of the SafetyOne by thoroughly fa

Strany 14 - General specifications

LOGIC 5-62 ●Muting lamp outputs: Y17 and Y20 Muting lamp outputs are used to control muting lamps. Intended outputs (Terminal names) Target safety in

Strany 15 - Chapter 2

LOGIC 5-63 Chapter 5 Wiring example (Logic 11d) In the case where 2 safety light curtains, 4 muting sensors, and 2 emergency stop switches are connect

Strany 16 - Locking ring

LOGIC 5-64 When not using the start switch(Auto start)When not detecting the welding of start switch(Manual start)When detecting the welding of start

Strany 17 - Applicable standards

LOGIC 5-65 Chapter 5 Timing chart (Logic 11d) Example: Manual start input (X16) is used. Safety input 1:X0, X1Start input 1: X16(Manual)Safety output

Strany 18 - Safety performance

LOGIC 5-66 Example: Control start input (X17) is used. Safety input 1:X0, X1Start input 2: X17(Control)Monitor output forsafety input 1: Y4Monitor ou

Strany 20 - Start input specifications

LOGIC 5-68 Logic 102: Partial stop logic for apparatus with openings Overview (Logic 102) This logic is for using safety devices with dual channel sol

Strany 21 - Safety output specifications

LOGIC 5-69 Chapter 5 Logic circuit (logic 102) Y0Y1Y2Y3Safety output 1Safety output 2T0, X0, T1, X1Safety input 1X6,X7X10,X11X12,X13T14, X14T15, X15X1

Strany 22 - Warning

LOGIC 5-70 Functions (Logic 102) ●Safety inputs: X0 to X13 (T0 to T5) Safety inputs are used to diagnose the status of connected safety devices, such

Strany 23 - Internal

LOGIC 5-71 Chapter 5 ●External device monitor inputs: X14 and X15 (T14 and T15) External device monitor inputs are used to diagnose the status of dev

Strany 24 - Logic number

OVERVIEW 1-2 Features of the SafetyOne z You can configure safety circuits without the use of complicated external wiring or special software, thereb

Strany 25 - Indicators

LOGIC 5-72 ●Start inputs: X16 and X17 Start inputs are used to control the start of safety outputs. Intended inputs (Terminal names) Target safet

Strany 26

LOGIC 5-73 Chapter 5 ●Safety outputs: Y0 to Y3 Safety outputs are used to output safety information processed by SafetyOne. Intended outputs (Termi

Strany 27 - Caution

LOGIC 5-74 ●Safety input monitor outputs: Y4 to Y11 Safety input monitor outputs are used to output the status of safety inputs in SafetyOne. Intende

Strany 28 - Connector specifications

LOGIC 5-75 Chapter 5 ●Solenoid outputs: Y17 and Y20 Solenoid outputs are used to control a solenoid in ian nterlock switch. Intended outputs (Termina

Strany 29

LOGIC 5-76 Wiring example (Logic 102) In the case where 2 emergency stop switches, 1 interlock switch with solenoid (spring lock type), and 3 safety l

Strany 30

LOGIC 5-77 Chapter 5 When not using the start switch(Auto start)When not detecting the welding of start switch(Manual start)When detecting the welding

Strany 31 - WARNIG and CAUTION

LOGIC 5-78 Timing chart (Logic 102) Example: Manual start input (X16) is used. OFF delay timeOFF delay timeSafety input 1: X0Start input 1: X16(Manual

Strany 32

LOGIC 5-79 Chapter 5 Example: Control start input (X17) is used. OFF delay timeOFF delay timeSafety input 1: X0Start input 2: X17(Control)Safety outpu

Strany 33 - Installation method

LOGIC 5-80 Logic 12A: The logic for apparatus with a two-hand control device Overview (Logic 12A) This logic is for using two hand input devices for s

Strany 34

LOGIC 5-81 Chapter 5 Logic circuit (logic 12A) Y0X0, X1X2, X3T4, X4, T5, X5T6, X6, T7, X7T12, X12, T13, X13T10, X10, T11, X11T14, X14T15, X15X16X1 7Y1

Strany 35 -  Installing on DIN Rails

PRODUCT SPECIFICATIONS 2-1 Chapter 2 Chapter2 PRODUCT SPECIFICATIONS This chapter describes product specifications of the SafetyOne. Parts Descriptio

Strany 36 - Wiring method

LOGIC 5-82 Functions (Logic 12A) ●Safety inputs: X0 to X13 (T4 to T13) Safety inputs are used to diagnose the status of connected safety devices, s

Strany 37 - Chapter 3

LOGIC 5-83 Chapter 5 Warning For connected control devices, refer to “SAFETY PRECAUTIONS”. Safety check signals (pulses signals) are sent from the d

Strany 38

LOGIC 5-84 ●Start inputs: X16 and X17 Start inputs are used to control the start of safety outputs. Intended inputs (Terminal names) Target safety

Strany 39 - Chapter4 BASIC OPERATIONS

LOGIC 5-85 Chapter 5 ●Safety outputs: Y0 to Y3 Safety outputs are used to output safety information processed by SafetyOne. Intended outputs (Termi

Strany 40

LOGIC 5-86 ●Safety input monitor outputs: Y4 to Y11 Safety input monitor outputs are used to output status of safety inputs in SafetyOne. Intended ou

Strany 41 - Using the protective cover

LOGIC 5-87 Chapter 5 ●State monitor outputs: Y14 to Y16 State monitor outputs are used to output the internal state of SafetyOne. State Intended outp

Strany 42 - Logic configuration

LOGIC 5-88 Wiring example (Logic 12A) In the case where 2 safety light curtains, 1 emergency stop switch, 1 interlock switch with solenoid (spring loc

Strany 43 - (Blinking)

LOGIC 5-89 Chapter 5 When not using the start switch(Auto start)When not detecting the welding of start switch(Manual start)When detecting the welding

Strany 44 - Timer configuration

LOGIC 5-90 Timing chart (Logic 12A) Example: Manual start input (X16) is used. Min. 0.1sSafety input 1: X0,X1Start input 1: X16(Manual)Safety output 1

Strany 45

LOGIC 5-91 Chapter 5 Example: Control start input (X17) is used. Safety input 1: X0,X1Start input 2: X17(Control)Safety output 1:Y0, Y1Monitor output

Strany 46

PRODUCT SPECIFICATIONS 2-2 General specifications Operating conditions Operating temperature (Surrounding air temperature) -10 to +55 ºC (no freezing

Strany 47 - Canceling the Stop state

LOGIC 5-92 Logic 12b: The logic constructing an OR circuit for various apparatus Overview (Logic 12b) This logic is for constructing an OR circuit of

Strany 48 - BASIC OPERATIONS

LOGIC 5-93 Chapter 5 Logic circuit (logic 12b) Safety input 1T0, T1, X0, X1ContorlStartControlY0Y1Y2Y3Safety output 1Safety output 2Safety input 2T4,

Strany 49 - Chapter5 LOGIC

LOGIC 5-94 Functions (Logic 12b) ●Safety inputs: X0 to X13 (T0 to T13) Safety inputs are used to diagnose the status of connected safety devices, suc

Strany 50

LOGIC 5-95 Chapter 5 Warning For connected control devices, refer to “SAFETY PRECAUTIONS”. Safety check signals (pulses signals) are sent from the d

Strany 51

LOGIC 5-96 ●External device monitor inputs: X14 and X15 (T14 and T15) External device monitor inputs are used to diagnose the status of devices conne

Strany 52 - M : Motor

LOGIC 5-97 Chapter 5 ●Start inputs: X16 and X17 Start inputs are used to control the start of safety outputs. Intended inputs (Terminal names) Ta

Strany 53

LOGIC 5-98 ●Safety outputs: Y0 to Y3 Safety outputs are used to output safety information processed by SafetyOne. Intended outputs (Terminal names)

Strany 54 - Overview (Logic 101)

LOGIC 5-99 Chapter 5 ●Safety input monitor outputs: Y4 to Y11 Safety input monitor outputs are used to output the status of safety inputs in SafetyOn

Strany 55 - Logic circuit (Logic 101)

LOGIC 5-100 ●Solenoid outputs: Y17 and Y20 Solenoid outputs are used to control a solenoid in an interlock switch. Intended outputs (Terminal names)

Strany 56 - Functions (Logic 101)

LOGIC 5-101 Chapter 5 Wiring example (Logic 12b) In the case where 2 safety switches, enabling switches, 1 emergency stop switch, and 1 interlock swit

Strany 57

PRODUCT SPECIFICATIONS 2-3 Chapter 2 Note1. Time to shut OFF safety outputs after safety inputs are turned OFF or input monitor error is detected (in

Strany 58

LOGIC 5-102 When not using the start switch(Auto start)When not detecting the welding of start switch(Manual start)When detecting the welding of start

Strany 59

LOGIC 5-103 Chapter 5 Timing chart (Logic 12b) Example: Manual start input (X16) is used. Safety input 1: X0Start input 1: X16(Manual)Monitor output f

Strany 60

LOGIC 5-104 Example: Control start input (X17) is used. Safety input 1: X0Start input 2: X17(Control)Monitor output forsafety input 1: Y4State monitor

Strany 61

LOGIC 5-105 Chapter 5

Strany 62 - Wiring example (Logic 101)

LOGIC 5-106 Logic 12C: The logic constructing an OR circuit for apparatus with openings Overview (Logic 12C) This logic is for constructing an OR circ

Strany 63

LOGIC 5-107 Chapter 5 Logic circuit (logic 12C) Safety input 1T0, T1, X0, X1ControlStartControlY0Y1Y2Y3Safety output 1Safety output 2X2, X3Safety inpu

Strany 64 - Timing chart (Logic 101)

LOGIC 5-108 Functions (Logic 12C) ●Safety inputs: X0 to X13 (T0, T1, T4, T5, and T10 to T13) Safety inputs are used to diagnose the status of connect

Strany 65

LOGIC 5-109 Chapter 5 Warning For connected control devices, refer to “SAFETY PRECAUTIONS”. Safety check signals (pulses signals) are sent from the

Strany 66 - Overview (Logic 11A)

LOGIC 5-110 ●External device monitor inputs: X14 and X15 (T14 and T15) External device monitor inputs are used to diagnose the status of devices conn

Strany 67 - Logic circuit (Logic 11A)

LOGIC 5-111 Chapter 5 ●Start inputs: X16 and X17 Start inputs are used to control the start of safety outputs. Intended inputs (Terminal names) T

Strany 68 - Functions (Logic 11A)

PRODUCT SPECIFICATIONS 2-4 Dimensions Detail of locking ringLocking ring

Strany 69

LOGIC 5-112 ●Safety outputs: Y0 to Y3 Safety outputs are used to output safety information processed by SafetyOne. Intended outputs (Terminal names

Strany 70

LOGIC 5-113 Chapter 5 ●Safety input monitor outputs: Y4 to Y11 Safety input monitor outputs are used to output the status of safety inputs in SafetyO

Strany 71

LOGIC 5-114 ●Solenoid outputs: Y17 and Y20 Solenoid outputs are used to control a solenoid in an interlock switch. Intended outputs (Terminal names)

Strany 72

LOGIC 5-115 Chapter 5 Wiring example (Logic 12C) In the case where 1 limit switch, 2 safety light curtains, 1 interlock switch, 1 emergency stop switc

Strany 73

LOGIC 5-116 When not using the start switch(Auto start)When not detecting the welding of start switch(Manual start)When detecting the welding of start

Strany 74 - Wiring example (Logic 11A)

LOGIC 5-117 Chapter 5 Timing chart (Logic 12C) Example: Manual start input (X16) is used. Min. 0.1sMax. 0.1sSafety input 1: X0Start input 1: X16(Manua

Strany 75

LOGIC 5-118 Example: Control start input (X17) is used. Safety input 1: X0Start input 2: X17(Control)Monitor output forsafety input 1: Y4State monitor

Strany 77

LOGIC 5-120 Logic 12d: Partial control logic for apparatus with openings Overview (Logic 12d) This logic is for constructing partial control of safety

Strany 78 - Overview (Logic 11b)

LOGIC 5-121 Chapter 5 Logic circuit (logic 12d) Y0T4, X4, T5, X5T6, X6, T7, X7X10, X11T2, X2, T3, X3T0, X0, T1, X1T14, X14T15, X15X12X13Y1Y2Y3Safety o

Strany 79 - Logic circuit (Logic 11b)

PRODUCT SPECIFICATIONS 2-5 Chapter 2 Applicable standards Standard Title IEC 61508 Part1-7 Functional safety of electrical/electronic/programmable el

Strany 80 - Functions (Logic 11b)

LOGIC 5-122 Functions (Logic 12d) ●Safety inputs: X0 to X11 (T0 to T7) Safety inputs are used to diagnose the status of connected safety devices, suc

Strany 81

LOGIC 5-123 Chapter 5 Warning For connected control devices, refer to “SAFETY PRECAUTIONS”. Safety check signals (pulses signals) are sent from the

Strany 82

LOGIC 5-124 ●Start inputs: X12 and X13 Start inputs are used to control the start of safety outputs. Intended inputs (Terminal names) Target safe

Strany 83

LOGIC 5-125 Chapter 5 ●Safety outputs: Y0 to Y3 Safety outputs are used to output safety information processed by SafetyOne. Intended outputs (Term

Strany 84

LOGIC 5-126 ●Safety input monitor outputs: Y4 to Y10 Safety input monitor outputs are used to output status of safety inputs in SafetyOne. Intended o

Strany 85

LOGIC 5-127 Chapter 5 ●State monitor outputs: Y14 to Y16 State monitor outputs are used to output the internal state of SafetyOne. State Intended out

Strany 86 - Wiring example (Logic 11b)

LOGIC 5-128 Wiring example (Logic 12d) In the case where 1 emergency stop switch, 3 interlock switches, and 1 safety light curtain are connected. S1

Strany 87

LOGIC 5-129 Chapter 5 When not using the start switch(Auto start)When not detecting the welding of start switch(Manual start)When detecting the weldin

Strany 88 - Timing chart (Logic 11b)

LOGIC 5-130 Timing chart (Logic 12d) Example: Manual start input (X12) is used. Min. 0.1sSafety output 2:Y2, Y3Monitor output forSafety output 2: Y13S

Strany 89

LOGIC 5-131 Chapter 5 Example: Control start input (X13) is used. Safety output 2:Y2, Y3Monitor output forSafety output 2: Y13Safety output 1:Y0, Y1M

Strany 90 - Overview (Logic 11C)

PRODUCT SPECIFICATIONS 2-6 Safety performance In the case of using safety outputs as dual channel outputs, SafetyOne can be used in a system for contr

Strany 91 - Logic circuit (Logic 11C)

LOGIC 5-132 Logic 103: Partial stop logic applicable for selection of active safety input devices Overview (Logic 103) For production machines, robots

Strany 92 - Functions (Logic 11C)

LOGIC 5-133 Chapter 5 Logic circuit (Logic 103) Safety input 2Teache modeAuto modeY2Y3Y0Y1Safety output 1Safety output 2 T6, X6, T7, X7Safety input 4

Strany 93

LOGIC 5-134 Functions (Logic 103) ●Safety inputs: X0 to X13 (T0, T2 to T7, T12, T13) Safety inputs are used to diagnose the status of connected safet

Strany 94

LOGIC 5-135 Chapter 5 Intended inputs (Terminal names) Function Function name Dual channel safety input Symbol Dual Channel Safety Description of op

Strany 95

LOGIC 5-136 ●External device monitor inputs: X14 and X15 (T14 and T15) External device monitor inputs are used to diagnose status of the devices conn

Strany 96

LOGIC 5-137 Chapter 5 ●Safety outputs: Y0 to Y3 Safety outputs are used to output safety information processed by SafetyOne. Intended outputs (Term

Strany 97

LOGIC 5-138 ●Safety output monitor outputs: Y12 and Y13 Safety output monitor outputs are used to output the status of safety outputs in SafetyOne. I

Strany 98 - Wiring example (Logic 11C)

LOGIC 5-139 Chapter 5 ●Solenoid outputs: Y17 and Y20 Solenoid outputs are used to control a solenoid in an interlock switch. The operations of soleno

Strany 99

LOGIC 5-140 Wiring example (Logic 103) In the case where 1 selector switch, 2 enabling switches, 1 safety light curtain, 1 emergency stop switch, and

Strany 100 - Timing chart (Logic 11C)

LOGIC 5-141 Chapter 5 When not using the start switch(Auto start)When using the start switch(Manual start)When connecting multiple emergency stop swit

Strany 101 - Chapter 5

PRODUCT SPECIFICATIONS 2-7 Chapter 2 Safety input specifications Drive terminal specifications (T0, T1, T2, T3, T4, T5, T6, T7, T10, T11, T12, T13, T1

Strany 102 - Overview (Logic 11d)

LOGIC 5-142 Timing chart (Logic 103) Example: Teach mode Max. 0.1sMonitor output forsafety input 4: Y7Safety input 4: X6,X7Safety output 2:Y2, Y3Safet

Strany 103 - Logic circuit (Logic 11d)

LOGIC 5-143 Chapter 5 Example: Auto mode Monitor output forsafety input 4: Y7Safety input 4: X6,X7Safety output 2:Y2, Y3Safety input 1: X0(Mode select

Strany 104 - Functions (Logic 11d)

LOGIC 5-144 Logic 13A: The logic applicable for selection of active safety input devices Overview (Logic 13A) For production machines, robots, and the

Strany 105 - Muting input

LOGIC 5-145 Chapter 5 Logic circuit (Logic 13A) Safety input 1T0, X0, X1Teach modeAuto modeControlStartControlT2, X2, T3, X3Safety input 2T4, X4, T5,

Strany 106 - External Device

LOGIC 5-146 Functions (Logic 13A) ●Safety inputs: X0 to X13 (T0, T2 to T13) Safety inputs are used to diagnose the status of connected safety devices

Strany 107 - Single Channel

LOGIC 5-147 Chapter 5 Warning For connected control devices, refer to “SAFETY PRECAUTIONS”. Safety check signals (pulses signals) are sent from the

Strany 108 - Off delay

LOGIC 5-148 ●Start inputs: X16 and X17 Start inputs are used to control the start of safety outputs. Intended inputs (Terminal names) Target safety

Strany 109

LOGIC 5-149 Chapter 5 ●Safety outputs: Y0 to Y3 Safety outputs are used to output safety information processed by SafetyOne. Intended outputs (Term

Strany 110

LOGIC 5-150 Safety input monitor outputs: Y4 to Y11 Safety input monitor outputs are used to output the status of safety inputs in SafetyOne. Intende

Strany 111 - Wiring example (Logic 11d)

LOGIC 5-151 Chapter 5 ●State monitor outputs: Y14 to Y16 State monitor outputs are used to output the internal state of SafetyOne. State Intended out

Strany 113 - Timing chart (Logic 11d)

PRODUCT SPECIFICATIONS 2-8 Start input specifications Rated input voltage 24V DC Input ON voltage 15.0V DC to 28.8V DC Input OFF voltage Open or 0V

Strany 114

LOGIC 5-152 Wiring example (Logic 13A) In the case where 1 selector switch, 1 enabling switch, 1 interlock switch with solenoid (spring lock type), an

Strany 115

LOGIC 5-153 Chapter 5 When using the start switch S7(Manual start)When not using the start switch S7(Auto start)When connecting multiple emergency sto

Strany 116 - Overview (Logic 102)

LOGIC 5-154 Timing chart (Logic 13A) Example: Teach mode Safety output 2: Y2,Y3Safety input 2: X2Monitor output forsafety input 2: Y5Monitor output f

Strany 117 - Logic circuit (logic 102)

LOGIC 5-155 Chapter 5 Example: Auto mode Safety output 2:Y2, Y3Monitor output forsafety input 3: Y6Monitor output forsafety input 1: Y4Monitor output

Strany 118 - Dual Channel Safety

LOGIC 5-156 Logic 13b: The logic constructing an OR circuit applicable for selection of active safety input devices Overview (Logic 13b) For productio

Strany 119

LOGIC 5-157 Chapter 5 Operation example (Logic 13b) Auto mode Beamsblocked!WorkspaceAuto modeTeach modeSafety input 1Safety input 6Safety input 2Saf

Strany 120

LOGIC 5-158 Logic circuit (Logic 13b) Safety input 1T0, X0, X1Teache modeAuto modeY0Y1Y2Y3Safety output 1Safety output 2T2, X2, T3, X3Safety input 2T4

Strany 121

LOGIC 5-159 Chapter 5 Functions (Logic 13b) ●Safety inputs: X0 to X13 (T0, T2 to T5, T12, T13) Safety inputs are used to diagnose the status of conne

Strany 122

LOGIC 5-160 Intended inputs (Terminal names) Function Function name Dual channel safety input Symbol Dual Channel Safety Description of operation T

Strany 123

LOGIC 5-161 Chapter 5 ●External device monitor inputs: X14 and X15 (T14 and T15) External device monitor inputs are used to diagnose status of the de

Strany 124 - Wiring example (Logic 102)

PRODUCT SPECIFICATIONS 2-9 Chapter 2 Safety output specifications Output type Source output (N channel MOSFET) Rated output voltage Power supply vol

Strany 125

LOGIC 5-162 ●Start inputs: X16 and X17 Start inputs are used to control the start of safety outputs. Intended inputs (Terminal names) Target safety

Strany 126 - Timing chart (Logic 102)

LOGIC 5-163 Chapter 5 ●Safety outputs: Y0 to Y3 Safety outputs are used to output safety information processed by SafetyOne. Intended outputs (Term

Strany 127

LOGIC 5-164 Safety input monitor outputs: Y4 to Y11 Safety input monitor outputs are used to output the status of safety inputs in SafetyOne. Intende

Strany 128 - System runs

LOGIC 5-165 Chapter 5 ●State monitor outputs: Y14 to Y16 State monitor outputs are used to output the internal state of SafetyOne. State Intended out

Strany 129

LOGIC 5-166 Wiring example (Logic 13b) In the case where 1 selector switch, 1 enabling switch, 1 interlock switch with solenoid (spring lock type), 2

Strany 130 - Functions (Logic 12A)

LOGIC 5-167 Chapter 5 When using the start switch S7(Manual start)When not using the start switch S7(Auto start)When connecting multiple emergency sto

Strany 131

LOGIC 5-168 Timing chart (Logic 13b) Example: Teach mode Safety output 2:Y2, Y3Safety input 2: X2Monitor output forsafety input 2: Y5Monitor output f

Strany 132

LOGIC 5-169 Chapter 5 Example: Auto mode Safety output 2: Y2,Y3Safety input 1: X0(Mode select input:Teach mode)Safety input 4:X6Monitor output forsafe

Strany 133

LOGIC 5-170 Logic 13C: Partial stop logic applicable for selection of active safety input devices Overview (Logic 13C) For production machines, robots

Strany 134

LOGIC 5-171 Chapter 5 Logic circuit (Logic 13C) Safety input 1T0, X0, X1Teache modeAuto modeModeSelectY0Y1Y2Y3Safety output 1Safety output 2T2, X2, T3

Strany 135

PRODUCT SPECIFICATIONS 2-10 Monitor output specifications Output type Source output (N channel MOSFET) Rated output voltage Power supply voltage Min

Strany 136 - Wiring example (Logic 12A)

LOGIC 5-172 Functions (Logic 13C) ●Safety inputs: X0 to X13 (T0, T2 to T11) Safety inputs are used to diagnose the status of connected safety devices

Strany 137

LOGIC 5-173 Chapter 5 Intended inputs (Terminal names) Function Function name Dual channel safety input Symbol Dual Channel Safety Description of op

Strany 138 - Timing chart (Logic 12A)

LOGIC 5-174 ●External device monitor inputs: X14 and X15 (T14 and T15) External device monitor inputs are used to diagnose status of the devices conn

Strany 139

LOGIC 5-175 Chapter 5 ●Start inputs: X16 and X17 Start inputs are used to control the start of safety outputs. Intended inputs (Terminal names) Tar

Strany 140 - Overview (Logic 12b)

LOGIC 5-176 ●Safety outputs: Y0 to Y3 Safety outputs are used to output safety information processed by SafetyOne. Intended outputs (Terminal names

Strany 141 - Logic circuit (logic 12b)

LOGIC 5-177 Chapter 5 Safety input monitor outputs: Y4 to Y11 Safety input monitor outputs are used to output the status of safety inputs in SafetyOn

Strany 142 - Functions (Logic 12b)

LOGIC 5-178 ●State monitor outputs: Y14 to Y16 State monitor outputs are used to output the internal state of SafetyOne. State Intended outputs (Term

Strany 143

LOGIC 5-179 Chapter 5 Wiring example (Logic 13C) In the case where 1 selector switch, 1 enabling swithc, 2 interlock switch with solenoid (spring lock

Strany 144

LOGIC 5-180 When using the start switch S7(Manual start)When not using the start switch S7(Auto start)When connecting multiple emergency stop switches

Strany 145

LOGIC 5-181 Chapter 5 Timing chart (Logic 13C) Example: Teach mode Max. 6sInitializationMonitor output forSafety output 1: Y12State monitor output 3:

Strany 146

PRODUCT SPECIFICATIONS 2-11 Chapter 2 Solenoid/Lamp output specifications Output type Source output (N channel MOSFET) Rated output voltage Power su

Strany 147

LOGIC 5-182 Example: Auto mode Monitor output forSafety output 1: Y12State monitor output 3:Y16Safety input 1: X0(Mode select input:Teach mode)Safety

Strany 148

LOGIC 5-183 Chapter 5

Strany 149 - Wiring example (Logic 12b)

LOGIC 5-184 Logic 13d: The logic applicable for selection of active safety input devices Overview (Logic 13d) For production machines, robots, and the

Strany 150

LOGIC 5-185 Chapter 5 Logic circuit (Logic 13d) Safety input 4T6,X6,T7,X7Safety input 3T2,X2,X3T14,X14T15,X15X10,X11Safety input 2Safety input 1Safety

Strany 151 - Timing chart (Logic 12b)

LOGIC 5-186 Functions (Logic 13d) ●Safety inputs: X0 to X13 (T0, T2, T4 to T7, T12, T13) Safety inputs are used to diagnose the status of connected s

Strany 152 - OFF delay tim e

LOGIC 5-187 Chapter 5 Intended inputs (Terminal names) Function Function name Dual channel direct opening input Symbol Dual ChannelDirect Opening De

Strany 153

LOGIC 5-188 ●External device monitor inputs: X14 and X15 (T14 and T15) External device monitor inputs are used to diagnose status of the devices conn

Strany 154 - Overview (Logic 12C)

LOGIC 5-189 Chapter 5 ●Start inputs: X16 and X17 Start inputs are used to control the start of safety outputs. Intended inputs (Terminal names) Tar

Strany 155 - Logic circuit (logic 12C)

LOGIC 5-190 ●Safety outputs: Y0 to Y3 Safety outputs are used to output safety information processed by SafetyOne. Intended outputs (Terminal names

Strany 156 - Direct Opening

LOGIC 5-191 Chapter 5 Safety input monitor outputs: Y4 to Y11 Safety input monitor outputs are used to output the status of safety inputs in SafetyOn

Strany 157

PRODUCT SPECIFICATIONS 2-12 Logic number The logic number of the SafetyOne is composed by a 3-digit code as following. Example 1: LOGIC No.104 The fir

Strany 158

LOGIC 5-192 ●State monitor outputs: Y14 to Y16 State monitor outputs are used to output the internal state of SafetyOne. State Intended outputs (Term

Strany 159

LOGIC 5-193 Chapter 5 Wiring example (Logic 13d) In the case where 2 selector switches, 2 enabling switches, 1 safety light curtains, and 1 emergency

Strany 160

LOGIC 5-194 When using the start switch S7(Manual start)When not using the start switch S7(Auto start)When connecting multiple emergency stopswitches

Strany 161

LOGIC 5-195 Chapter 5 Timing chart (Logic 13d) Example: TEACH 1 Max. 6sInitializationMonitor output forSafety output 1: Y12State monitor output 3:Y16S

Strany 162

LOGIC 5-196 Example: TEACH 2 Monitor output forSafety output 1: Y12State monitor output 3:Y16Safety input 1: X0(Mode select input:T each 1)Safety inp

Strany 163 - Wiring example (Logic 12C)

LOGIC 5-197 Chapter 5 Example: Auto mode Max. 3sMonitor output forSafety output 1: Y12State monitor output 3:Y16Safety input 2: X2(Mode select input:T

Strany 164

LOGIC 5-198 Logic 104: Partial stop logic applicable for selection of active safety input devices Overview (Logic 104) For production machines, robots

Strany 165 - Timing chart (Logic 12C)

LOGIC 5-199 Chapter 5 Logic circuit (Logic 104) Safety input 1T0, X0, X1Teach modeAuto modeY0Y1Y2Y3Safety input 2T12, X12T13, X13X16X1 7Safety input 5

Strany 166 - OFF delay time OFF delay time

LOGIC 5-200 Function (Logic 104) ●Safety inputs: X0 to X11 (T0, T2 to T11) Safety inputs are used to diagnose the status of connected safety devices,

Strany 167

LOGIC 5-201 Chapter 5 Warning For connected control devices, refer to “SAFETY PRECAUTIONS”. Safety check signals (pulses signals) are sent from the

Strany 168 - Overview (Logic 12d)

PRODUCT SPECIFICATIONS 2-13 Chapter 2 Indicators 0.1.512515 30SAFE- INTIMER(S)SAFE- OUTSOLENOID-OUTSTART- INX0 X1X2 X3X4X5X6 X7X10 X11X12 X13X14 X15X1

Strany 169 - Logic circuit (logic 12d)

LOGIC 5-202 ●Start inputs: X16 and X17 Start inputs are used to control the start of safety outputs. Intended inputs (Terminal names) Target safety

Strany 170 - Functions (Logic 12d)

LOGIC 5-203 Chapter 5 ●Safety outputs: Y0 to Y3 Safety outputs are used to output safety information processed by SafetyOne. Intended outputs (Term

Strany 171

LOGIC 5-204 Safety input monitor outputs: Y4 to Y10 Safety input monitor outputs are used to output the status of safety inputs in SafetyOne. Intende

Strany 172

LOGIC 5-205 Chapter 5 ●State monitor outputs: Y14 to Y16 State monitor outputs are used to output the internal state of SafetyOne. State Intended out

Strany 173

LOGIC 5-206 Wiring example (Logic 104) In the case where 1 selector switch, 1 enabling switch, 2 interlock switches, and 1 emergency stop switch are c

Strany 174

LOGIC 5-207 Chapter 5 When using the start switch S6(Manual start)When not using the start switch S6(Auto start)When connecting multiple emergency sto

Strany 175

LOGIC 5-208 Timing chart (Logic 104) Example: Teach mode Max. 6sInitializationMonitor output for Safetyoutput 1-1: Y12State monitor output 3:Y16Safety

Strany 176 - Wiring example (Logic 12d)

LOGIC 5-209 Chapter 5 Example: Auto mode Monitor output forSafety output 1-1: Y12State monitor output 3:Y16Safety input 1: X0(Mode select input :Teach

Strany 177

LOGIC 5-210 Logic 14A: Partial stop logic applicable for selection of active safety input devices Overview (Logic 14A) For production machines, robots

Strany 178 - Timing chart (Logic 12d)

LOGIC 5-211 Chapter 5 Logic circuit (Logic 14A) Safety input 1T0, X0, X1Teach modeAuto modeY0Y1Y2Y3T2, X2, T3, X3Safety input 2T4, X4, T5, X5T6, X6, T

Strany 179

PRODUCT SPECIFICATIONS 2-14 (3) Timer LED Indication Status Descriptions 0 ON No OFF-delay (safety outputs shut off immediately) .1 ON OFF-dela

Strany 180 - Overview (Logic 103)

LOGIC 5-212 Function (Logic 14A) ●Safety inputs: X0 to X11 (T0, T2 to T11) Safety inputs are used to diagnose the status of connected safety devices,

Strany 181 - Logic circuit (Logic 103)

LOGIC 5-213 Chapter 5 Warning For connected control devices, refer to “SAFETY PRECAUTIONS”. Safety check signals (pulses signals) are sent from the

Strany 182 - Functions (Logic 103)

LOGIC 5-214 ●Start inputs: X16 and X17 Start inputs are used to control the start of safety outputs. Intended inputs (Terminal names) Target safety

Strany 183

LOGIC 5-215 Chapter 5 ●Safety outputs: Y0 to Y3 Safety outputs are used to output safety information processed by SafetyOne. Intended outputs (Term

Strany 184

LOGIC 5-216 Safety input monitor outputs: Y4 to Y10 Safety input monitor outputs are used to output the status of safety inputs in SafetyOne. Intende

Strany 185

LOGIC 5-217 Chapter 5 ●State monitor outputs: Y14 to Y16 State monitor outputs are used to output the internal state of SafetyOne. State Intended out

Strany 186

LOGIC 5-218 Wiring example (Logic 14A) In the case where 1 selector switch, 1 enabling switch, 2 emergency stop switches, and 1 interlock switch are c

Strany 187

LOGIC 5-219 Chapter 5 When using the start switch S6(Manual start)When not using the start switch S6(Auto start)When connecting multiple emergency sto

Strany 188 - Wiring example (Logic 103)

LOGIC 5-220 Timing chart (Logic 14A) Example: Teach mode Safety input 1: X0(Mode select input :Teach mode)Safety input 2: X2Monitor output forsafety i

Strany 189

LOGIC 5-221 Chapter 5 Example: Auto mode Safety input 1: X0(Mode select input :Teach mode)Safety input 2:X2, X3Monitor output forsafety input 2: Y5Mon

Strany 190 - Timing chart (Logic 103)

PRODUCT SPECIFICATIONS 2-15 Chapter 2 Specification of configuration switches (1) Logic switch The logic switch is an 8-digit DIP switch for us

Strany 191

LOGIC 5-222 Logic 14b: Partial stop logic applicable for selection of active safety input devices Overview (Logic 14b) For production machines, robots

Strany 192 - Overview (Logic 13A)

LOGIC 5-223 Chapter 5 Logic circuit (Logic 14b) Safety input 1T0, X0, X1Teach modeAuto modeY0Y1Y2Y3Safety input 2T12, X12T13, X13X16X17Safety input 5S

Strany 193 - Logic circuit (Logic 13A)

LOGIC 5-224 Function (Logic 14b) ●Safety inputs: X0 to X11 (T0, T2 to T11) Safety inputs are used to diagnose the status of connected safety devices,

Strany 194 - Functions (Logic 13A)

LOGIC 5-225 Chapter 5 Warning For connected control devices, refer to “SAFETY PRECAUTIONS”. Safety check signals (pulses signals) are sent from the

Strany 195

LOGIC 5-226 ●Start inputs: X16 and X17 Start inputs are used to control the start of safety outputs. Intended inputs (Terminal names) Target safety

Strany 196

LOGIC 5-227 Chapter 5 ●Safety outputs: Y0 to Y3 Safety outputs are used to output safety information processed by SafetyOne. Intended outputs (Term

Strany 197

LOGIC 5-228 Safety input monitor outputs: Y4 to Y10 Safety input monitor outputs are used to output the status of safety inputs in SafetyOne. Intende

Strany 198

LOGIC 5-229 Chapter 5 ●State monitor outputs: Y14 to Y16 State monitor outputs are used to output the internal state of SafetyOne. State Intended out

Strany 199

LOGIC 5-230 Wiring example (Logic 14b) In the case where 1 selector switch, 1 enabling switch, 2 interlock switches, and 1 emergency stop switch are c

Strany 200 - Wiring example (Logic 13A)

LOGIC 5-231 Chapter 5 When using the start switch S6(Manual start)When not using the start switch S6(Auto start)When connecting multiple emergency sto

Strany 201

PRODUCT SPECIFICATIONS 2-16 Connector specifications Input connector Connector type: - Spring clamp connector (30 poles) FS9Z-CN0

Strany 202 - Timing chart (Logic 13A)

LOGIC 5-232 Timing chart (Logic 14b) Example: Teach mode Safety input 1: X0(Mode select input :Teach mode)Safety input 2: X2Monitor output forsafety i

Strany 203

LOGIC 5-233 Chapter 5 Example: Auto mode 0.1s to 5sMax. 0.1sSafety input 1: X0(Mode select input :Teach mode)Safety input 2: X2,X3Monitor output forsa

Strany 204 - Overview (Logic 13b)

LOGIC 5-234 Logic 14C: Partial stop logic applicable for selection of active safety input devices Overview (Logic 14C) For production machines, robots

Strany 205 - System stops

LOGIC 5-235 Chapter 5 Logic circuit (Logic 14C) Safety input 1T0, X0, X1Teach modeAuto modeY0Y1Y2Y3Safety input 2T12, X12T13, X13X16X1 7Safety input 5

Strany 206 - Logic circuit (Logic 13b)

LOGIC 5-236 Function (Logic 14C) ●Safety inputs: X0 to X11 (T0, T2 to T11) Safety inputs are used to diagnose the status of connected safety devices,

Strany 207 - Functions (Logic 13b)

LOGIC 5-237 Chapter 5 Warning For connected control devices, refer to “SAFETY PRECAUTIONS”. Safety check signals (pulses signals) are sent from the

Strany 208

LOGIC 5-238 ●Start inputs: X16 and X17 Start inputs are used to control the start of safety outputs. Intended inputs (Terminal names) Target safety

Strany 209

LOGIC 5-239 Chapter 5 ●Safety outputs: Y0 to Y3 Safety outputs are used to output safety information processed by SafetyOne. Intended outputs (Term

Strany 210

LOGIC 5-240 ●Safety input monitor outputs: Y4 to Y10 Safety input monitor outputs are used to output the status of safety inputs in SafetyOne. Intend

Strany 211

LOGIC 5-241 Chapter 5 ●State monitor outputs: Y14 to Y16 State monitor outputs are used to output the internal state of SafetyOne. State Intended out

Strany 212

PRODUCT SPECIFICATIONS 2-17 Chapter 2 Y1Y1Y3Y3Y5Y5Y7Y7Y1Y111Y1Y133Y1Y155Y1Y177N.CN.CV-FEFEY0Y0Y2Y2Y4Y4Y6Y6Y1Y100Y1Y122Y1Y144Y1Y166Y20Y20V+FEFE Output

Strany 213

LOGIC 5-242 Wiring example (Logic 14C) In the case where 1 selector switch, 2 enabling switches, 2 interlock switches, and 1 emergency stop switch are

Strany 214 - Wiring example (Logic 13b)

LOGIC 5-243 Chapter 5 When using the start switch S6(Manual start)When not using the start switch S6(Auto start)When connecting multiple emergency sto

Strany 215

LOGIC 5-244 Timing chart (Logic 14C) Example: Teach mode Safety input 1: X0(Mode select input :Teach mode)Safety input 2: X2Monitor output forsafety i

Strany 216 - Timing chart (Logic 13b)

LOGIC 5-245 Chapter 5 Example: Auto mode Safety input 1: X0(Mode select input :Teach mode)Safety input 2:X2, X3Monitor output forsafety input 2: Y5Mon

Strany 217 - Example: Auto mode

LOGIC 5-246 Logic 14d: Partial stop logic applicable for selection of active safety input devices for apparatus with openings Overview (Logic 14d) For

Strany 218 - Overview (Logic 13C)

LOGIC 5-247 Chapter 5 Logic circuit (Logic 14d) Safety input 1T0, X0, X1Teach modeAuto modeY0Y1Y2Y3Safety output1Safety output3-1Safety input 2X10, X1

Strany 219 - Logic circuit (Logic 13C)

LOGIC 5-248 Function (Logic 14d) ●Safety inputs: X0 to X11 (T0, T2 to T7) Safety inputs are used to diagnose the status of connected safety devices,

Strany 220 - Functions (Logic 13C)

LOGIC 5-249 Chapter 5 Intended inputs (Terminal names) Function Function name Dual channel safety input Symbol Dual Channel Safety Description of op

Strany 221

LOGIC 5-250 ●External device monitor inputs: X12 to X15 (T12 to T15) External device monitor inputs are used to diagnose status of the devices connec

Strany 222

LOGIC 5-251 Chapter 5 ●Start inputs: X16 and X17 Start inputs are used to control the start of safety outputs. Intended inputs (Terminal names) Tar

Strany 223

SAFETY PRECAUTIONS z Carefully read this user’s manual to ensure correct operation before starting installation, wiring, operation, maintenance, and

Strany 224

PRODUCT SPECIFICATIONS 2-18

Strany 225

LOGIC 5-252 ●Safety outputs: Y0 to Y3 Safety outputs are used to output safety information processed by SafetyOne. Intended outputs (Terminal names

Strany 226

LOGIC 5-253 Chapter 5 ●Safety input monitor outputs: Y4 to Y10 Safety input monitor outputs are used to output the status of safety inputs in SafetyO

Strany 227 - Wiring example (Logic 13C)

LOGIC 5-254 ●State monitor outputs: Y14 to Y16 State monitor outputs are used to output the internal state of SafetyOne. State Intended outputs (Term

Strany 228

LOGIC 5-255 Chapter 5 Wiring example (Logic 14d) In the case where 1 selector switch, 1 enabling switch, 1 interlock switch, 1 emergency stop switch,

Strany 229 - Timing chart (Logic 13C)

LOGIC 5-256 When using the start switch S6(Manual start)When not using the start S6(Auto start)When connecting multiple emergency stop switches in ser

Strany 230

LOGIC 5-257 Chapter 5 Timing chart (Logic 14d) Example: Teach mode Safety input 1: X0(Mode select input :Teach mode)Safety input 2: X2Monitor output f

Strany 231

LOGIC 5-258 Example: Auto mode Safety input 1: X0(Mode select input :Teach mode)Safety input 3:X4, X5Monitor output forsafety input 3: Y6Monitor outp

Strany 233 - Logic circuit (Logic 13d)

LOGIC 5-260 Logic 105: Partial stop logic for apparatus with openings Overview (Logic 105) This logic is for using safety devices with dual channel so

Strany 234 - Functions (Logic 13d)

LOGIC 5-261 Chapter 5 Logic circuit (Logic 105) Y0X0, X1X2, X3X4, X5X6, X7X10, X11T14, X14T15, X15X16X1 7Y1Y2Y3Safety output 1Safety output 2Safety in

Strany 235

INSTALLATION AND WIRING 3-1 Chapter 3 Chapter3 INSTALLATION AND WIRING This chapter describes methods and precautions for installing and wiring the Sa

Strany 236

LOGIC 5-262 Functions (Logic 105) ●Safety inputs: X0 to X11 Safety inputs are used to diagnose the status of connected safety devices, such as emerge

Strany 237

LOGIC 5-263 Chapter 5 ●External device monitor inputs: X12 to X15 (T12 to T15) External device monitor inputs are used to diagnose the status of devi

Strany 238

LOGIC 5-264 ●Start inputs: X16 and X17 Start inputs are used to control the start of safety outputs. Intended inputs (Terminal names) Target safety

Strany 239

LOGIC 5-265 Chapter 5 ●Safety outputs: Y0 to Y3 Safety outputs are used to output safety information processed by SafetyOne. Intended outputs (Term

Strany 240

LOGIC 5-266 ●Safety input monitor outputs: Y4 to Y10 Safety input monitor outputs are used to output the status of safety inputs in SafetyOne. Intend

Strany 241 - Wiring example (Logic 13d)

LOGIC 5-267 Chapter 5 ●State monitor outputs: Y14 to Y16 State monitor outputs are used to output the internal state of SafetyOne. State Intended out

Strany 242

LOGIC 5-268 Wiring example (Logic 105) In the case where 1 emergency stop switch and 4 safety light curtains are connected. S1 :Emergency stop switc

Strany 243 - Timing chart (Logic 13d)

LOGIC 5-269 Chapter 5 When not using the start switch S6(Auto start)When using the start switch S6(Manual start)When not using some safety inputs・If s

Strany 244 - Example: TEACH 2

LOGIC 5-270 Timing chart (Logic 105) Safety input1:X0Start input 2: X17(Control)Monitor output forsafety input 1: Y4Safety input1:X1note 1)note 1)Saf

Strany 245

LOGIC 5-271 Chapter 5

Strany 246 - Overview (Logic 104)

INSTALLATION AND WIRING 3-2  Environment for using the SafetyOne is “Pollution degree 2”. Use SafetyOne in environments of pollution degree 2 (accor

Strany 247 - Logic circuit (Logic 104)

LOGIC 5-272 Logic 106: Partial stop logic for apparatus with openings Overview (Logic 106) This logic is for using safety devices with dual channel s

Strany 248 - Function (Logic 104)

LOGIC 5-273 Chapter 5 Logic circuit (Logic 106) Y0X0, X1X2, X3X4, X5X6, X7X10, X11T14, X14T15, X15X16X17Y1Y2Y3Safety output 1Safety output 2Safety inp

Strany 249

LOGIC 5-274 Functions (Logic 106) ●Safety inputs: X0 to X11 Safety inputs are used to diagnose the status of connected safety devices, such as emerge

Strany 250

LOGIC 5-275 Chapter 5 ●External device monitor inputs: X12 to X15 (T12 to T15) External device monitor inputs are used to diagnose the status of devi

Strany 251

LOGIC 5-276 ●Start inputs: X16 and X17 Start inputs are used to control the start of safety outputs. Intended inputs (Terminal names) Target safety

Strany 252

LOGIC 5-277 Chapter 5 ●Safety outputs: Y0 to Y3 Safety outputs are used to output safety information processed by SafetyOne. Intended outputs (Term

Strany 253

LOGIC 5-278 ●Safety input monitor outputs: Y4 to Y10 Safety input monitor outputs are used to output the status of safety inputs in SafetyOne. Intend

Strany 254 - Wiring example (Logic 104)

LOGIC 5-279 Chapter 5 ●State monitor outputs: Y14 to Y16 State monitor outputs are used to output the internal state of SafetyOne. State Intended out

Strany 255

LOGIC 5-280 Wiring example (Logic 106) In the case where 1 emergency stop switch and 4 safety light curtains are connected. S1 :Emergency stop switc

Strany 256 - Timing chart (Logic 104)

LOGIC 5-281 Chapter 5 When not using the start switch S6(Auto start)When using the start switch S6(Manual start)When not using some safety inputs・If s

Strany 257

INSTALLATION AND WIRING 3-3 Chapter 3 Installation method  Installation location and direction When the SafetyOne is installed in an enclosure, confi

Strany 258 - Inactive

LOGIC 5-282 Timing chart (Logic 106) Safety input1:X0Monitor output forsafety input 1: Y4Safety input1:X1note 1)note 1)Safety output 1: Y0Safety input

Strany 260 - Function (Logic 14A)

LOGIC 5-284 Logic 107: Partial stop logic for various apparatus Overview (Logic 107) This logic is for safety protective measures applicable to produc

Strany 261

LOGIC 5-285 Chapter 5 Logic circuit (Logic107) T0, X0, T1, X1T2, X2, T3, X3T4, X4, T5, X5T6, X6, T7, X7T10, X10, T11, X11T14, X14T15, X15X16X1 7Safety

Strany 262

LOGIC 5-286 Functions (Logic 107) ●Safety inputs: X0 to X11 (T0 to T11) Safety inputs are used to diagnose the status of connected safety devices, su

Strany 263

LOGIC 5-287 Chapter 5 ●External device monitor inputs: X12 to X15 (T12 to T15) External device monitor inputs are used to diagnose the status of devi

Strany 264

LOGIC 5-288 ●Start inputs: X16 and X17 Start inputs are used to control the start of safety outputs. Intended inputs (Terminal names) Target safe

Strany 265

LOGIC 5-289 Chapter 5 ●Safety outputs: Y0 to Y3 Safety outputs are used to output safety information processed by SafetyOne. Intended outputs (Term

Strany 266 - Wiring example (Logic 14A)

LOGIC 5-290 ●Safety input monitor outputs: Y4 to Y10 Safety input monitor outputs are used to output the status of safety inputs in SafetyOne. Intend

Strany 267

LOGIC 5-291 Chapter 5 ●State monitor outputs: Y14 to Y16 State monitor outputs are used to output the internal state of SafetyOne. State Intended out

Strany 268 - Timing chart (Logic 14A)

INSTALLATION AND WIRING 3-4 BNL6 mounting clip Mount SafetyOne on a vertical plane as shown in Fig.3.2. All other installation directions are not all

Strany 269

LOGIC 5-292 Wiring example (Logic 107) In the case where 1 emergency stop switch and 4 interlock switches are connected. S1 :Emergency stop switch S

Strany 270 - Overview (Logic 14b)

LOGIC 5-293 Chapter 5 When not using the start switch(Auto start)When not detecting the welding of start switch(Manual start)When detecting the weldin

Strany 271 - Logic circuit (Logic 14b)

LOGIC 5-294 Timing chart (Logic 107) Example: Manual start input (X16) is used. Max. 0.1sSafety input 1: X0Safety output 1-1:Y0Monitor output forsafet

Strany 272 - Function (Logic 14b)

LOGIC 5-295 Chapter 5 Example: Control start input (X17) is used. Max. 0.1sSafety input 1: X0Safety output 1-1:Y0Monitor output forsafety input 1: Y4M

Strany 273

LOGIC 5-296 Logic 108: Partial stop logic applicable for selection of active safety input devices in apparatus with openings Overview (Logic 108) For

Strany 274

LOGIC 5-297 Chapter 5 Logic circuit (Logic 108) Safety input 1T0, X0, X1Teach modeAuto modeY0Y1Y2Y3Safety output1-1Safety output2-1Safety input 2X10,

Strany 275

LOGIC 5-298 Functions (Logic 108) ●Safety inputs: X0 to X11 (T0, T2 to T7) Safety inputs are used to diagnose the status of connected safety devices,

Strany 276

LOGIC 5-299 Chapter 5 Intended inputs (Terminal names) Function Function name Dual channel safety input Symbol Dual Channel Safety Description of op

Strany 277

LOGIC 5-300 ●External device monitor inputs: X12 to X15 (T12 to T15) External device monitor inputs are used to diagnose status of the devices connec

Strany 278 - Wiring example (Logic 14b)

LOGIC 5-301 Chapter 5 ●Start inputs: X16 and X17 Start inputs are used to control the start of safety outputs. Intended inputs (Terminal names) Tar

Strany 279

INSTALLATION AND WIRING 3-5 Chapter 3  Installing on DIN Rails Mount and remove SafetyOne on 35mm-wide DIN rails according to the following instruct

Strany 280 - Timing chart (Logic 14b)

LOGIC 5-302 ●Safety outputs: Y0 to Y3 Safety outputs are used to output safety information processed by SafetyOne. Intended outputs (Terminal names

Strany 281

LOGIC 5-303 Chapter 5 ●Safety input monitor outputs: Y4 to Y10 Safety input monitor outputs are used to output the status of safety inputs in SafetyO

Strany 282 - Overview (Logic 14C)

LOGIC 5-304 ●State monitor outputs: Y14 to Y16 State monitor outputs are used to output the internal state of SafetyOne. State Intended outputs (Term

Strany 283 - Logic circuit (Logic 14C)

LOGIC 5-305 Chapter 5 Wiring example (Logic108) In the case where 1 selector switch, 1 enabling switch, 1 interlock switch, 1 emergency stop switch, a

Strany 284 - Function (Logic 14C)

LOGIC 5-306 When using the start switch S6(Manual start)When not using the start switch S6(Auto start)When connecting multiple emergency stop switches

Strany 285

LOGIC 5-307 Chapter 5 Timing chart (Logic 108) Example: Teach mode Safety input 1: X0(Mode select input :Teach mode)Safety input 2: X2Monitor output f

Strany 286

LOGIC 5-308 Example: Auto mode Safety input 1: X0(Mode select input :Teach mode)Safety input 2:X2, X3Monitor output forsafety input 2: Y5Monitor outpu

Strany 287

LOGIC 5-309 Chapter 5 Logic functions This section describes the functions of each logic circuit. The logic functions are separated into input, logic

Strany 288

LOGIC 5-310 Type Function Symbol Description Reference page AND & This function means logical (AND) of multiple inputs. 5-327 OR >=1 This

Strany 289

LOGIC 5-311 Chapter 5 Input functions Dual channel direct opening input This function is for connecting safety devices with dual channel direct openin

Strany 290 - Wiring example (Logic 14C)

INSTALLATION AND WIRING 3-6 Wiring method SafetyOne has two kinds of connectors spring clamp (optional) and crimp.Note1 Note1. For detailed informatio

Strany 291

LOGIC 5-312 Error detection function Input monitoring When an error is detected between dual channel inputs, the SafetyOne changes to the Protection

Strany 292 - Timing chart (Logic 14C)

LOGIC 5-313 Chapter 5 Dual channel dependent input This function is for connecting safety devices with dual channel dependent action mechanisms, such

Strany 293

LOGIC 5-314 Error detection function Input monitoring When an error is detected between dual channel inputs, the SafetyOne changes to the Protection

Strany 294 - Overview (Logic 14d)

LOGIC 5-315 Chapter 5 Dual channel NO/NC input This function is for connecting safety devices with dual channel NO/NC mechanisms, such as non-contact

Strany 295 - Logic circuit (Logic 14d)

LOGIC 5-316 Error detection function Input monitoring and grounding detection When an error is detected between the dual channel inputs, the SafetyOn

Strany 296 - Function (Logic 14d)

LOGIC 5-317 Chapter 5 Dual channel safety input This function is for connecting a safety device with a dual channel solid state output (PNP output), s

Strany 297

LOGIC 5-318 XnXn+1InONOFFInput monitor errordetection time:Max.0.1sIndependent conditonchange in one inputYm(Monitor output)SafetyOne changes toProtec

Strany 298

LOGIC 5-319 Chapter 5 Mode select input This function is for connecting devices with a mode select function, such as a selector switch. As shown in Fi

Strany 299

LOGIC 5-320 Error detection function Input monitoring When an error is detected at the inputs, the SafetyOne changes to the Protection state and disp

Strany 300

LOGIC 5-321 Chapter 5 Mode select input II This function is for connecting devices with a mode select function, such as a selector switch. In case of

Strany 301

INSTALLATION AND WIRING 3-7 Chapter 3  Wiring for spring clamp connector Do not wire the connector while it is connected to the SafetyOne, as this ca

Strany 302

LOGIC 5-322 Inputswitching time:Max.3sXnXn+1TEACHONOFFYm(Monitor output)SafetyOne changes toProtection State after an inputmonitor error is

Strany 303 - Wiring example (Logic 14d)

LOGIC 5-323 Chapter 5 Muting input This function is for connecting a muting sensor with a solid state output (PNP output) or a mechanical contact devi

Strany 304

LOGIC 5-324 XnXn+1InONOFFInput monitor errordetection time:Max.3sIndependent conditonchange in one inputYm(Monitor output)SafetyOne changes toProtecti

Strany 305 - Timing chart (Logic 14d)

LOGIC 5-325 Chapter 5 Monitor input This function is for connecting a switch (mechanical contact device) or sensor with a solid state output (PNP outp

Strany 306

LOGIC 5-326 External device monitoring input This function is for monitoring external devices controlled by the SafetyOne. External devices can be dia

Strany 307

LOGIC 5-327 Chapter 5 LOGIC FUNCTION AND As shown in Fig. 5-18 and 5-19, this function reflects the results of a logic (AND) function processing for m

Strany 308 - Overview (Logic 105)

LOGIC 5-328 XOR As shown in Fig. 5-22 and 5-23, this function reflects the results of an exclusive logic (XOR) function processing for multiple inputs

Strany 309 - Logic circuit (Logic 105)

LOGIC 5-329 Chapter 5 Muting II This function adds muting to connected safety devices. As shown in Fig. 5-26, this function is comprised of a safety i

Strany 310 - Functions (Logic 105)

LOGIC 5-330 Control start This function confirms operation of the connected start input device. As shown in Fig.5-28, this function is comprised of a

Strany 311

LOGIC 5-331 Chapter 5 Two hand control This function adds a two hand control function to the connected the safety device. As shown in Fig.5-30, this f

Strany 312

INSTALLATION AND WIRING 3-8

Strany 313

LOGIC 5-332 Output function Safety output without timer This function is for controlling the safety output. As shown in Fig. 5-32, this function is co

Strany 314

LOGIC 5-333 Chapter 5 OnInYn1s①ⅠⅡYn'ⅡYn:Safety OutputYn':Monitor Output(Safety Output)1s②OFFONOFFONOFFONOFFON Fig.5-33 Operation timing of

Strany 315

LOGIC 5-334 Error detection function EDM input monitoring When the following condition is satisfied, the SafetyOne changes to the Protection state an

Strany 316 - Wiring example (Logic 105)

LOGIC 5-335 Chapter 5 Safety output with timer This function is for controlling the safety output with OFF delay timer. As shown in Fig. 5-35, this fu

Strany 317

LOGIC 5-336 OnInYnDelay timer setting time:0.1~30s1s①ⅠⅡYn'ⅡⅢYn:Safety outputYn':Monitor output(Safety output)1s②OFFONOFFONOFFONOFFON Fig.5-

Strany 318 - Timing chart (Logic 105)

LOGIC 5-337 Chapter 5 Error detection function EDM input monitoring When the following condition is satisfied, the SafetyOne changes to the Protection

Strany 319

LOGIC 5-338

Strany 320 - Overview (Logic 106)

TROUBLE SHOOTING 6-1Chapter 6 Chapter6 TROUBLE SHOOTING This chapter describes how to determine the cause of a failure or error that occurs with the

Strany 321 - Logic circuit (Logic 106)

TROUBLE SHOOTING 6-2 5 ON OFF OFF Muting lamp error (broken wire) (For logic 11d only) 1. Broken wire of muting lamp wiring 2. Broken wire of Mutin

Strany 322 - Functions (Logic 106)

APPENDIX A-1 APPENDIX APPENDIX Minimum Distance The minimum distance is the distance required to minimize the risk of contact with the hazard in the d

Strany 323

BASIC OPERATIONS 4-1 Chapter 4 Chapter4 BASIC OPERATIONS This chapter describes the basic operations of SafetyOne. Make proper use of the SafetyOne by

Strany 324

APPENDIX A-2 Example in which the direction of entry is perpendicular to the safety light curtain AccessDanger ZoneProtectiveArea Limit - When the s

Strany 325

APPENDIX A-3 APPENDIX Example in which the direction of entry is horizontal to the safety light curtain AccessDanger ZoneProtectiveArea Limit Use th

Strany 326

APPENDIX A-4 Example in which the direction of entry is at an angle to the safety light curtain 侵入方向AccessProtectiveArea LimitDanger Zone The angle o

Strany 327

APPENDIX A-5 APPENDIX For ANSI B11.19 Use the following formula to calculate the minimum distance. S = K × ( Ts + Tc + Tr + Tbm ) + Dpf Tr = t1 + t

Strany 328 - Wiring example (Logic 106)

APPENDIX A-6 Maintenance and Inspection Warning To ensure safety, use the SafetyOne after performing inspections described below and confirming that

Strany 329

APPENDIX A-7 APPENDIX Type number Item Type number Module FS1A-C11S Accessories Item Type number Quantity Input connector FS9Z-CN01 1 Output connec

Strany 330 - Timing chart (Logic 106)

APPENDIX A-8 DECLARATION OF CONFORMITY Document No. : D1B103, D3B18 We, IDEC CORPORATION 7-31, Nishimiyahara 1-Chome Yodogawa-Ku, Osaka 532-8550

Strany 332 - Overview (Logic 107)

FS1A-C11S SafetyOne User’s manual (Original instructions) ● B-1218(1) ● February, 2010 ● 1-7-31 Nishi-Miyahara, Yodo

Strany 334 - Functions (Logic 107)

Warning z Calculate respective safety distances, taking into consideration the response time of the SafetyOne, safety devices to be connected to

Strany 335

BASIC OPERATIONS 4-2 (1) Random display of Initial state. (2) Output and LED display of the selected logic. (3) Blinking LED display of the select

Strany 336

www .idec.com ©2009-2010 IDEC CORPORATION All Rights Reserved.Manual No. FS9Z-B1218-1 2/2010 UNITED STATES IDEC CORPORATION1175 Elko Drive, Sunnyval

Strany 337

BASIC OPERATIONS 4-3 Chapter 4 Turning on the power After the SafetyOne is turned on, it transitions to the Initial state and checks internal circuits

Strany 338

BASIC OPERATIONS 4-4 Logic configuration The SafetyOne offers 24 types of logic, and by performing the logic configuration procedure listed below, you

Strany 339

BASIC OPERATIONS 4-5 Chapter 4 3. Confirm the configuration and press the enter button. Confirm that the selected logic switch matches the blinking lo

Strany 340 - Wiring example (Logic 107)

BASIC OPERATIONS 4-6 Timer configuration SafetyOne has an OFF-delay timer function that retains safety outputs during the configured time and after th

Strany 341

BASIC OPERATIONS 4-7 Chapter 4 3. Confirm the configuration and press the enter button. Confirm that the selected timer switch matches the blinking t

Strany 342 - Timing chart (Logic 107)

BASIC OPERATIONS 4-8 Canceling the Protection state SafetyOne transitions to the Protection state if a failure is detected in an external device or an

Strany 343

BASIC OPERATIONS 4-9 Chapter 4 Canceling the Stop state If the SafetyOne detects any wiring errors, abnormalities or internal circuit failure, it chan

Strany 345 - Logic circuit (Logic 108)

LOGIC 5-1 Chapter 5 Chapter5 LOGIC This chapter describes the Logics in the SafetyOne. Make proper use of the SafetyOne by thoroughly familiarizing yo

Strany 346 - Functions (Logic 108)

Warning z Do not connect devices having input and output specifications that do not satisfy the requirements of the SafetyOne. Refer to the follow

Strany 347

LOGIC 5-2 Logic Logic No.Interlock switch・Emergency stop switch Enabling switch Mode selection Safety light curtain Muting function NO/NC contact de

Strany 348

LOGIC 5-3 Chapter 5 Safety performance on each wiring of inputs and outputs Applicable safety performance of SafetyOne depends on wiring of the inputs

Strany 349

LOGIC 5-4 • Wiring example of safety outputs K1Y0K2Y1X14T14K1 K20V DCControl category 4MTTFd 100 yearsDC highPL eK2K1MK : ContactorM : MotorSafetyOne

Strany 350

LOGIC 5-5 Chapter 5 • Wiring example of a SafetyOne and a SafetyOne Y0X0X1T0T1Y1Control category 4MTTFd 100 yearsDC highPL eSafetyOne1SafetyOne2Dual C

Strany 351

LOGIC 5-6 Logic 101: The logic for various apparatus Overview (Logic 101) This logic is for safety protective measures applicable to production machin

Strany 352

LOGIC 5-7 Chapter 5 Logic circuit (Logic 101) Y0T0, X0, T1, X1T2, X2, T3, X3T4, X4, T5, X5T6, X6, T7, X7T12, X12, T13, X13T14, X14T15, X15X16X17Y1Y2Y3

Strany 353 - Wiring example (Logic108)

LOGIC 5-8 Functions (Logic 101) ●Safety inputs: X0 to X13 (T0 to T13) Safety inputs are used to diagnose the status of connected safety devices, such

Strany 354

LOGIC 5-9 Chapter 5 ●External device monitor inputs: X14 and X15 (T14 and T15) External device monitor inputs are used to diagnose the status of devi

Strany 355 - Timing chart (Logic 108)

LOGIC 5-10 ●Start inputs: X16 and X17 Start inputs are used to control the start of safety outputs. Intended inputs (Terminal names) Target safet

Strany 356

LOGIC 5-11 Chapter 5 ●Safety outputs: Y0 to Y3 Safety outputs are used to output safety information processed by SafetyOne. Intended outputs (Termi

Strany 357 - Logic functions

Caution z SafetyOne is designed for installation within an enclosure. Do not install SafetyOne outside an enclosure. Install SafetyOne in enclosu

Strany 358 - Self-hold

LOGIC 5-12 ●Safety input monitor outputs: Y4 to Y11 Safety input monitor outputs are used to output the status of safety inputs in SafetyOne. Intende

Strany 359 - Input functions

LOGIC 5-13 Chapter 5 ●Solenoid outputs: Y17 and Y20 Solenoid outputs are used to control a solenoid in an interlock switch. Intended outputs (Termina

Strany 360 - Error detection function

LOGIC 5-14 Wiring example (Logic 101) In the case where 3 interlock switches, 2 interlock switches with solenoid (spring lock type), and 1 emergency s

Strany 361 - Dual channel dependent input

LOGIC 5-15 Chapter 5 When not using the start switch(Auto start)When not detecting the welding of start switch(Manual start)When detecting the welding

Strany 362

LOGIC 5-16 Timing chart (Logic 101) Example: Manual start input (X16) is used. Example: Control start input (X17) is used. Safety input

Strany 364

LOGIC 5-18 Logic 11A: The logic for apparatus with openings Overview (Logic 11A) This logic is for using safety devices with dual channel solid state

Strany 365 - Description of operation

LOGIC 5-19 Chapter 5 Logic circuit (Logic 11A) Y0X0, X1X2, X3X4, X5X6, X7T12, X12, T13, X13T10, X10, T11, X11T14, X14T15, X15X16X17Y1Y2Y3Safety output

Strany 366

LOGIC 5-20 Functions (Logic 11A) ●Safety inputs: X0 to X13 (T10 to T13) Safety inputs are used to diagnose the status of connected safety devices, su

Strany 367 - Mode select input

LOGIC 5-21 Chapter 5 ●External device monitor inputs: X14 and X15 (T14 and T15) External device monitor inputs are used to diagnose the status of dev

Strany 368

BEFORE GETTING STARTED Thank you for your purchase of the IDEC SafetyOne (Type Number FS1A-C11S). This user’s manual describes the specifications, a

Strany 369 - Mode select input II

LOGIC 5-22 ●Start inputs: X16 and X17 Start inputs are used to control the start of safety outputs. Intended inputs (Terminal names) Target safet

Strany 370

LOGIC 5-23 Chapter 5 ●Safety outputs: Y0 to Y3 Safety outputs are used to output safety information processed by SafetyOne. Intended outputs (Termi

Strany 371 - Connects to

LOGIC 5-24 ●Safety input monitor outputs: Y4 to Y11 Safety input monitor outputs are used to output status of safety inputs in SafetyOne. Intended ou

Strany 372

LOGIC 5-25 Chapter 5 ●Solenoid outputs: Y17 and Y20 Solenoid outputs are used to control a solenoid in an interlock switch. Intended outputs (Termina

Strany 373 - Monitor input

LOGIC 5-26 Wiring example (Logic 11A) In the case where 4 safety light curtains, 1 emergency stop switch, and 1 interlock switch with solenoid (spring

Strany 374

LOGIC 5-27 Chapter 5 When not using the start switch(Auto start)When not detecting the welding of start switch(Manual start)When detecting the welding

Strany 375 - LOGIC FUNCTION

LOGIC 5-28 Timing chart (Logic 11A) Example: Manual start input (X16) is used. Example: Control start input (X17) is used. Safety input 1

Strany 376

LOGIC 5-29 Chapter 5

Strany 377 - Muting II

LOGIC 5-30 Logic 11b: The logic for apparatus with NO/NC contact inputs Overview (Logic 11b) This logic function is for using dual channel NO/NC conta

Strany 378 - Control start

LOGIC 5-31 Chapter 5 Logic circuit (Logic 11b) Y0T0, X0, T1, X1T2, X2, T3, X3T4, X4, T5, X5T6, X6, T7, X7T12, X12, T13, X13T10, X10, T11, X11T14, X14T

Strany 379 - Two hand control

CONTENTS Chapter1 OVERVIEW ...

Strany 380 - Ex. Contactor, safety relay

LOGIC 5-32 Functions (Logic 11b) ●Safety inputs: X0 to X13 (T0 to T13) Safety inputs are used to diagnose the status of connected safety devices, suc

Strany 381

LOGIC 5-33 Chapter 5 Unused safety inputs Terminal names Connection X0-T0 Open Safety input 1 X1-T1 Short X2-T2 Open Safety input 2 X3-T3 Short X4-

Strany 382

LOGIC 5-34 ●Start inputs: X16 and X17 Start inputs are used to control the start of safety outputs. Intended inputs (Terminal names) Target safet

Strany 383

LOGIC 5-35 Chapter 5 ●Safety outputs: Y0 to Y3 Safety outputs are used to output safety information processed by SafetyOne. Intended outputs (Termi

Strany 384 - Delay timer

LOGIC 5-36 ●Safety input monitor outputs: Y4 to Y11 Safety input monitor outputs are used to output the status of safety inputs in SafetyOne. Intende

Strany 385

LOGIC 5-37 Chapter 5 ●Solenoid outputs: Y17 and Y20 Solenoid outputs are used to control the solenoid in interlock switch with lock. Intended outputs

Strany 386

LOGIC 5-38 Wiring example (Logic 11b) In the case where 4 non-contact interlock switches, 1 emergency stop switch, and 1 interlock switch with solenoi

Strany 387 - Chapter6 TROUBLE SHOOTING

LOGIC 5-39 Chapter 5 When not using the start switch(Auto start)When not detecting the welding of start switch(Manual start)When detecting the welding

Strany 388

LOGIC 5-40 Timing chart (Logic 11b) Example: Manual start input (X16) is used. Example: Control start input (X17) is used. Safety output

Strany 389 - Minimum Distance

LOGIC 5-41 Chapter 5

Strany 390 - Area Limit

Logic 12A: The logic for apparatus with a two-hand control device ... 5-80 Logic

Strany 391

LOGIC 5-42 Logic 11C: The logic for apparatus with openings Overview (Logic 11C) This logic is for using safety devices with dual channel solid state

Strany 392

LOGIC 5-43 Chapter 5 Logic circuit (Logic 11C) Y0X0, X1X2, X3T4, X4, T5, X5T6, X6, T7, X7T12, X12, T13, X13T10, X10, T11, X11T14, X14T15, X15X16X17Y1Y

Strany 393

LOGIC 5-44 Functions (Logic 11C) ●Safety inputs: X0 to X13 (T4 to T13) Safety inputs are used to diagnose the status of connected safety devices, suc

Strany 394 - Maintenance and Inspection

LOGIC 5-45 Chapter 5 ●External device monitor inputs: X14 and X15 (T14 and T15) External device monitor inputs are used to diagnose the status of dev

Strany 395 - Options (sold separately)

LOGIC 5-46 ●Start inputs: X16 and X17 Start inputs are used to control the start of safety outputs. Intended inputs (Terminal names) Target safety

Strany 396 - DECLARATION OF CONFORMITY

LOGIC 5-47 Chapter 5 ●Safety outputs: Y0 to Y3 Safety outputs are used to output safety information processed by SafetyOne. Intended outputs (Termi

Strany 397

LOGIC 5-48 ●Safety input monitor outputs: Y4 to Y11 Safety input monitor outputs are used to output the status of safety inputs in SafetyOne. Intende

Strany 398 - (Original instructions)

LOGIC 5-49 Chapter 5 ●Solenoid outputs: Y17 and Y20 Solenoid outputs are used to control a solenoid in an interlock switch. Intended outputs (Termina

Strany 399

LOGIC 5-50 Wiring example (Logic 11C) In the case where 2 safety light curtains 2 emergency stop switches, and 2 interlock switches with solenoid (spr

Strany 400

LOGIC 5-51 Chapter 5 When not using the start switch(Auto start)When not detecting the welding of start switch(Manual start)When detecting the welding

Komentáře k této Příručce

Žádné komentáře