Idec DATAVS2 Series Uživatelský manuál

Procházejte online nebo si stáhněte Uživatelský manuál pro Hardware Idec DATAVS2 Series. IDEC DATAVS2 Series User Manual Uživatelská příručka

  • Stažení
  • Přidat do mých příruček
  • Tisk

Shrnutí obsahu

Strany 1

Smart Vision Sensor INSTRUCTION MANUAL www.vision-sensors-illuminators.com

Strany 2

SVS2 Series Instruction Manual 5 4.3.2. Graphic User Interface Installation We recommend closing any programs that are currently r

Strany 3

Instruction Manual SVS2 Series 6 4.4. Communicating with the sensor Communication with the sensor occurs via the Ethernet network.

Strany 4

SVS2 Series Instruction Manual 7 If you use a direct connection: • From menu START select Control Panel Network Connections  LAN

Strany 5

Instruction Manual SVS2 Series 8 5. SENSOR SETUP 5.1. Configuring an inspection through the Graphic User Interface After launchin

Strany 6 - 1. GENERAL INFORMATION

SVS2 Series Instruction Manual 9 5.1.1. Menu bar Lets you load or save the inspection in .XML format on your personal computer a

Strany 7 - 2. ELECTRIC CONNECTIONS

Instruction Manual SVS2 Series 10 Sensor : The icons in this menu let you: • establish connection with sensor (Connect to SVS), •

Strany 8 - 1 2 3 4

SVS2 Series Instruction Manual 11 5.1.2. Tool bar Gives quick access to typical functions. It is divided into 4 sections: - The

Strany 9

Instruction Manual SVS2 Series 12 5.1.3. Setup bar The Setup bar lets you complete the system configuration procedure in 3 steps.

Strany 10

SVS2 Series Instruction Manual 13 As you search for and select connected sensors, the control panel displays sensor name, IP addres

Strany 11 - Notebook

Instruction Manual SVS2 Series 14 5.1.5. Images Buffer It lists the thumbs of images which have been previously acquired and/or dow

Strany 12

DATASENSOR S.p.A. Via Lavino 265 40050 Monte S. Pietro - Bologna - Italy Tel: +39 051 6765611 Fax: +3

Strany 13

SVS2 Series Instruction Manual 15 5.1.7. Inspection Explorer Move the mouse pointer to the upper edge of the Help window (pointer

Strany 14

Instruction Manual SVS2 Series 16 Click the symbol to collapse level. 5.1.8. Help The Help Panel pro

Strany 15

SVS2 Series Instruction Manual 17 You may expand all answers by clicking "Show All". Simply click "Hide Al

Strany 16

Instruction Manual SVS2 Series 18 6. EASY GRAPHIC USER INTERFACE - INITIAL SETUP Before you can operate the SVS2 system, you will h

Strany 17

SVS2 Series Instruction Manual 19 6.2. STEP 1 During this first step, you must decide how you want to go about the inspeection

Strany 18

Instruction Manual SVS2 Series 20 6.2.1. Off-Line Mode The control panel is activated: you need to define the "Reference

Strany 19

SVS2 Series Instruction Manual 21 6.2.2. On-Line Mode Here you need to select the sensor you wish to connect to. When you select

Strany 20

Instruction Manual SVS2 Series 22 When you create a new inspection ("New Inspection") in On-Line mode, this acquisition par

Strany 21

SVS2 Series Instruction Manual 23 Finally, selecting "Open Inspection from SVS" (available only in On-Line mode) gives a

Strany 22

Instruction Manual SVS2 Series 24 6.3. STEP 2 The section of the Setup bar dedicated to step 2 looks like this: Select Trigge

Strany 24

SVS2 Series Instruction Manual 25 6.4. STEP 3 In this final step of the configuration process, you may: • set output settings (Se

Strany 25

Instruction Manual SVS2 Series 26 Open the pull-down menu to display the different Output Modes. Output is Disabled by default.

Strany 26

SVS2 Series Instruction Manual 27 6.4.2. Test In this mode, inspection can be run in two different modalities: • Offline: using

Strany 27

Instruction Manual SVS2 Series 28 7. EASY GRAPHIC USER INTERFACE - EXPERT MODE So far, we have discussed Graphic User Interface ope

Strany 28

SVS2 Series Instruction Manual 29 8. GRAPHIC USER INTERFACE 8.1. Modes of operation There are two modes of operation available: •

Strany 29

Instruction Manual SVS2 Series 30 This option may be selected from the pull-down menu This type of trigger comes ha

Strany 30

SVS2 Series Instruction Manual 31 The controls use an absolute reference system, with the origin located in the top left corner of

Strany 31

Instruction Manual SVS2 Series 32 8.4.1. Position Locator Description It is also known as edge locator. Edge: Border of object di

Strany 32

SVS2 Series Instruction Manual 33 Parameters After clicking in the work area to create the ROI, the control panel displays the set

Strany 33

Instruction Manual SVS2 Series 34 Example Add a position locator to current inspection. Select "Position" from the pull-do

Strany 34

SVS2 Series Instruction Manual I TABLE OF CONTENTS 1. GENERAL INFORMATION ...

Strany 35 - INSPECTION

SVS2 Series Instruction Manual 35 8.4.2. Pattern Match Locator Description In pattern match operation, sample object and target

Strany 36

Instruction Manual SVS2 Series 36 After clicking in the work area to create the ROI, the control panel displays the set of parameter

Strany 37

SVS2 Series Instruction Manual 37 Example Add a Pattern Match locator to current inspection. Select "Pattern Match" from

Strany 38

Instruction Manual SVS2 Series 38 8.5. Controls The controls are tools used to set inspection specifications. The SVS2 system offe

Strany 39

SVS2 Series Instruction Manual 39 It is possible to set more complex inspection processes, with acquired images processed in paralle

Strany 40

Instruction Manual SVS2 Series 40 8.5.1. Brightness Description The term brightness signifies the "brightness" attribute

Strany 41 - STANDARD mode

SVS2 Series Instruction Manual 41 Parameters After clicking in the work area to create the ROI, the control panel displays the set

Strany 42

Instruction Manual SVS2 Series 42 Example Add "Brightness" control with rectangular ROI to current inspection. Select &quo

Strany 43 - Measurement

SVS2 Series Instruction Manual 43 8.5.2. Contrast Description The term contrast signifies the ratio of lightest to darkest pixel

Strany 44

Instruction Manual SVS2 Series 44 Parameters After clicking in the work area to create the ROI, the control panel displays the set o

Strany 45

Instruction Manual SVS2 Series II 10. INSPECTION SELECTION ...

Strany 46

SVS2 Series Instruction Manual 45 Example Add "Contrast" control with rectangular ROI to current inspection. Select "

Strany 47

Instruction Manual SVS2 Series 46 8.5.3. Contour Match Description The contour match operation consists in comparing the contour

Strany 48

SVS2 Series Instruction Manual 47 Parameters After clicking in the work area to create the ROI, the control panel displays the set

Strany 49

Instruction Manual SVS2 Series 48 Example Add "Contour Match" control to current inspection to detect the contour of a bri

Strany 50

SVS2 Series Instruction Manual 49 8.5.4. Edge Count Description This control identifies all edges (edge detection ►) located insi

Strany 51

Instruction Manual SVS2 Series 50 Please note that different parameters are available in the STANDARD and EXPERT modes: STANDAR

Strany 52

SVS2 Series Instruction Manual 51 Example Add an "Edge count" control to current inspection to identify up to two edges.

Strany 53

Instruction Manual SVS2 Series 52 8.5.5. Width Description This control is also termed "gauge" and lets you measure the

Strany 54

SVS2 Series Instruction Manual 53 STANDARD mode EXPERT mode • Name : Name assigned to control in Inspection Explorer. Maxi

Strany 55

Instruction Manual SVS2 Series 54 Example Add a "Width" edge to current inspection using the Graphic User Standard in STA

Strany 56

SVS2 Series Instruction Manual 1 1. GENERAL INFORMATION 1.1. Conventions used in the Manual This manual is intended as a clear,

Strany 57

SVS2 Series Instruction Manual 55 8.5.6. Pattern Match Description The term pattern match signifies a process that searches for a

Strany 58

Instruction Manual SVS2 Series 56 Parameters After clicking in the work area to create the ROI, the control panel displays the set o

Strany 59

SVS2 Series Instruction Manual 57 Example Add a "Pattern Match" control to current inspection. Select "Pattern Match

Strany 60

Instruction Manual SVS2 Series 58 8.5.7. Position Description This control identifies the object position edge (edge detection ►)

Strany 61

SVS2 Series Instruction Manual 59 Please note that different parameters are available in the STANDARD and EXPERT modes: STAND

Strany 62

Instruction Manual SVS2 Series 60 Add a "Position" control to current inspection to identify up to two edges. Select "

Strany 63

SVS2 Series Instruction Manual 61 9. TEACH BUTTON On the top of the sensor body there is a very important button with many functio

Strany 64

Instruction Manual SVS2 Series 62 10. INSPECTION SELECTION In order to change the current Inspection running on SVS you can choos

Strany 65

SVS2 Series Instruction Manual 63 10.2. Inspection selection through Digital Input To select the current inspection running on SV

Strany 66 - TEACH BUTTON

Instruction Manual SVS2 Series 64 The following SVS Settings dialog window will appear: In the bottom view on the dialog window th

Strany 67

Instruction Manual SVS2 Series 2 2. ELECTRIC CONNECTIONS M12 8-pole: (power supply and I/O) pin 1 : white : digital input 1 pin

Strany 68

SVS2 Series Instruction Manual 65 11. INSPECTIONS AND PERIODIC MAINTENANCE Correct system maintenance consists in removing dust or

Strany 69

Instruction Manual SVS2 Series 66 12. SPECIFICATIONS SVS2: Supply voltage: 24 VDC ± 10% Ripple voltage: 1 Vpp max with illuminat

Strany 70

SVS2 Series Instruction Manual 67 13. LIST OF AVAILABLE MODELS MODEL DESCRIPTION SVS2-06-DE-OBJ 6mm, ETHERNET CONN., OBJ SVS2-08-D

Strany 71

Instruction Manual SVS2 Series 68 15. ACCESSORIES ST-5066 U-shaped fixing bracket for angle adjustment ST-5068 L-shaped fixing br

Strany 72 - 14. OVERALL DIMENSIONS

SVS2 Series Instruction Manual 69 MODELLO DESCRIZIONE N° ORDINE SVS-ST-5068 U-shaped fixing bracket for angle adjustment 95A901320

Strany 73 - 15. ACCESSORIES

Instruction Manual SVS2 Series 70 16. TUTORIAL 16.1. ► Digital image Digitization allows real images acquired by a camera to be t

Strany 74

SVS2 Series Instruction Manual 71 16.2. ► Machine vision This is a specific branch of Computer Vision (or "artificial vision

Strany 75 - 16. TUTORIAL

Instruction Manual SVS2 Series 72 16.4. ► Lighting Options Ring light A technique with many application possibilities. The illumi

Strany 76

SVS2 Series Instruction Manual 73 16.5. ► Blob / Blob analysis A blob (blob stands for Binary Large Object) is a set of adjacent

Strany 77

Instruction Manual SVS2 Series 74 16.6. ► Binarization This is a process that converts any given image to a two-level image (in ou

Strany 78

SVS2 Series Instruction Manual 3 4. INSTALLATION 4.1. Hardware connections To ensure proper operation, never exceed device ratin

Strany 79

SVS2 Series Instruction Manual 75 16.7. ► Edge / Edge Detection The term "edge" signifies the contour of the object show

Strany 80

Instruction Manual SVS2 Series 76 16.8. ► Inspection times Total inspection duration depends on three factors: • exposure time (►);

Strany 81

SVS2 Series Instruction Manual 77 16.10. ► Pattern match In the pattern match method, a sample object is recognised by searching fo

Strany 82

Instruction Manual SVS2 Series 78 17. GLOSSARY • Algorithm : set of instructions that accomplish a task in a finite number of step

Strany 83 - 17. GLOSSARY

Instruction Manual SVS2 Series 4 4.2. Focusing ring In order to focus the area placed by the sensor you should use the transparent f

Komentáře k této Příručce

Žádné komentáře